Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Comparative syntheses of tetracycline-imprinted polymeric silicate and acrylate on CdTe quantum dots as fluorescent sensors
 
  • Details
Options

Comparative syntheses of tetracycline-imprinted polymeric silicate and acrylate on CdTe quantum dots as fluorescent sensors

Journal
Biosensors and Bioelectronics
Date Issued
2014-11-15
Author(s)
MU-JUNG CHAO
CHIUNG-WEN HU  
DOI
10.1016/j.bios.2014.05.058
URI
https://www.scopus.com/pages/publications/84902248502
https://scholars.csmu.edu.tw/handle/123456789/23006
Abstract
The amphoteric drug molecule tetracycline, which contains groups with pKa 3.4-9.9, was used as a template for conjugating molecularly imprinted polymers (MIPs) and as a quencher for CdTe quantum dot (QD) fluorescence. Two MIP-QD composites were synthesized by a sol-gel method using a silicon-based monomer and a monomer linker between the MIP and QD, i.e., tetraethoxylsilane/3-mercaptopropyltriethoxysilane (MPS) and tetraethoxylsilane/3-aminopropyltriethoxysilane (APS). Another MIP-QD composite was synthesized by the chain-growth polymerization of methacrylic acid (MAA) and an allyl mercaptan linker. The prepared MIP-QDs were characterized by FTIR and SEM and utilized at 0.33mg/mL to determine the tetracycline content in phosphate buffers (pH 7.4, 50mM) through the Perrin and Stern-Volmer models of quenching fluorometry. The Perrin model was applied to tetracycline concentrations of 7.4μM-0.37mM for MIP-MPS-QD, 7.4μM-0.12mM for MIP-APS-QD, and 7.4μM-0.10mM for MIP-MAA-QD (R2=0.9988, 0.9978, and 0.9931, respectively). The Stern-Volmer model was applied to tetracycline concentrations of 0.12-0.37mM for MIP-APS-QD (R2=0.9983) and 0.10-0.37mM for MIP-MAA-QD (R2=0.9970). The detection limits were 0.45μM, 0.54μM, and 0.50μM for MIP-MPS-QD, MIP-APS-QD, and MIP-MAA-QD, respectively. Equilibrium times, differences between imprinted and nonimprinted polymers, and MIP-QD quenching mechanisms were discussed. Finally, specificity studies demonstrated that MIP-MAA-QD exhibited optimal recoveries of 96% from bovine serum albumin (n=5, RSD=3.6%) and 91% from fetal bovine serum (n=5, RSD=4.8%).
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback