Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Bubble technique for evaluating effective dose of diagnostic X-rays
 
  • Details
Options

Bubble technique for evaluating effective dose of diagnostic X-rays

Other Title
A feasibility study
Journal
Journal of Radiation Research
Date Issued
2009-01-01
Author(s)
CHIEN-YI CHEN  
DOI
10.1269/jrr.08084
URI
https://www.scopus.com/pages/publications/71749106095
https://scholars.csmu.edu.tw/handle/123456789/24774
Abstract
This study examined the feasibility of applying the bubble technique to evaluate effective dose for diagnostic X-rays. A BTI-GAMMA bubble detector from Bubble Technology Industries was used for gamma detection. A multi-slab acrylic (PMMA) phantom was fabricated to quantify the effective dose E based on an ICRP-60 report. Accordingly, the bubble detectors were evaluated through preliminary tests to ascertain both the reproducibility of specific X-ray doses and the linearity of multiple X-ray doses. Qualified bubble detectors were then inserted into a multi-slab acrylic phantom. The positions of the inserted bubbles closely corresponded with the position of represented organs or tissues. The effective dose E of X-ray was determined in 12 organ and tissue samples. The bubble detector was maintained at either 21.5°C (for abdomen AP) or 22°C (for chest PA) to optimize counting, and the assessed effective doses for males and females were 66.75 ± 10.23 μSv and 66.47 ± 9.89 μSv, respectively, for each chest PA X-ray exposure. The abdominal AP X-ray exposure doses were 1183.73 ± 124.29 μSv and 976.70 ± 120.13 μSv for males and females, respectively. Controlling and holding the bubble detector at an optimal ambient temperature during X-ray exposure was the most important issue in practical application, and the optimal temperature had to be adjusted slightly with incident X-ray to effectively suppress the largest bubbles to enable easy reading.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback