Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. College of Medical Science and Technology/醫學科技學院
  3. School of Biomedical Sciences/生物醫學科學學系
  4. 探討針孔測試對臨床視光的新價值
 
  • Details
Options

探討針孔測試對臨床視光的新價值

Date Issued
2012
Author(s)
楊立健
Li-Chien
Advisor
鄭宏銘;陳伯易
;
URI
https://handle.ncl.edu.tw/11296/22s7cd
https://scholars.csmu.edu.tw/handle/123456789/5817
Abstract
屈光異常,在臨床上是常見的症狀。相較於其他的影響視力因子,屈光異常是一個最容易避免的問題,過去的研究認為可用針孔測試達到最佳屈光異常的矯正,而獲得最佳矯正視力,但是,環境照度對於針孔測試使用時的效應分析,尚有許多不足之處。因此,本研究釐清此議題並尋求針孔篩檢之最佳使用效率。本研究徵求30位受試者,年齡介於20至50歲之間。受試者在亮室(500 lux )與暗室(5 lux )之不同環境照度下進行視敏度之評估測試,並分別使用黑字視標( Black Target )與白字視標( White Target )進行比較,分析結果以student’s T test與Paired-T test進行統計檢定。研究結果發現,使用白字視標在暗室下(5 lux)沒有使用針孔所測得的VA值為0.63 ± 0.20,使用針孔後所測得的VA值為0.81 ± 0.23,前後所測得的相對平均改變量為38.82% ± 48.43 ( p < 0.001)。根據研究的結果經交叉比對分析,証實以針孔測試的方法在暗室白字視標下,可以做為預測是否達到最佳矯正視力的依據,這是針孔測試過去未曾被提出的全新應用價值。
Refraction errors are commonly found in clinical settings and are the most avoidable among all the factors that may affect vision. Previous researches have pointed out that pinhole can be used for the best correction of refraction errors. However, the use of pinhole to achieve best corrected visual acuity (BCVA) has not been extensively studied under different illumination conditions. This study aims to clarify this issue in an effort to achieve the best use of pinhole. A total of 30 volunteers, aged between 20 and 50, were recruited to assess visual acuity under 500 lux or 5 lux conditions, with black target or white target. The results were analyzed with student’s T test and Paired-T test. The average visual acuity achieved with white target under 5 lux was 0.63 ± 0.20 without pinhole, which was increased to 0.81 ± 0.23, showing a relative increase by 8.82% ± 48.43 ( p < 0.001 ). Furthermore, the results indicated that pinhole with white target under 5 lux may be used for prediction of whether BCVA had been achieved by the previous prescription. Thus, a novel use of pinhole was proposed.
Type
thesis
File(s)
No Thumbnail Available
Name

100CSMU5114008-001.zip

Size

10.09 MB

Format

Unknown

Checksum

(MD5):c5c5990a6aa101c62d195c39091e0f73

Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback