Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Development of focusing multi-knife-edge camera for proton beam range verification
 
  • Details
Options

Development of focusing multi-knife-edge camera for proton beam range verification

Other Title
A Monte Carlo study
Journal
Radiation Physics and Chemistry
Date Issued
2024-04-01
Author(s)
CHIH-CHIEH CHIANG  
DOI
10.1016/j.radphyschem.2024.111529
URI
https://www.scopus.com/pages/publications/85183113933
https://scholars.csmu.edu.tw/handle/123456789/26885
Abstract
Proton range uncertainties limit the ability to make full clinical use of the sharp distal falloff of the proton beam. To overcome this limitation, prompt gamma (PG) imaging system with mechanical collimation can be used in non-invasive proton beam range verification. In this study, we developed a focusing multi-knife-edge collimator to improve the counting efficiency and accuracy in detecting proton beam range. Unlike the common design of a single-knife-edge slit (SKE) collimator, the multi-knife-edge slit (MKE) collimator consists of three slits and focuses on the target detection area. To compare the performances of these two collimator designs, Monte Carlo simulation was unitized to model the cameras for measuring the PGs during proton irradiation. The simulation was performed using the GATE v9.1. The setup included a pencil beam of 100 MeV, 160 MeV, and 230 MV protons incident upon a cylindrical PMMA phantom with three different proton numbers of 107, 108, and 109. The detection PG profiles were fitted with a 3-line-segment fitting method to estimate the range of proton beams. Both cameras were aimed at the expected range depth for the corresponding proton beam energies. Experiments for range shifts were conducted by shifting the phantom between −20 mm and 20 mm along the beam axis. Results demonstrate that the MKE camera exhibits approximately twice the efficiency of the SKE camera in detecting PGs. In range shift retrieval, with the delivery of 108 protons, the MKE camera achieves submillimeter accuracy (except for incident protons at 230 MeV), while the SKE camera achieves accuracy within 2 mm. In conclusion, this study assesses the feasibility of the MKE camera and illustrates its potential application for range shift detection, contributing to precise range monitoring in proton therapy.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback