Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. The relation between oxygen consumption and the equilibrated inspired oxygen fraction in an anesthetic circle breathing system
 
  • Details
Options

The relation between oxygen consumption and the equilibrated inspired oxygen fraction in an anesthetic circle breathing system

Other Title
A mathematic formulation & laboratory simulations
Journal
Annals of Biomedical Engineering
Date Issued
2009-01-01
Author(s)
CHUNG-HAN HSIN  
DOI
10.1007/s10439-008-9593-x
URI
https://www.scopus.com/pages/publications/57349196432
https://scholars.csmu.edu.tw/handle/123456789/25783
Abstract
Measuring a patients' oxygen consumption (V·O2) is valuable in critical care and during anesthesia. Up to now, there has been no satisfactory equation describing the relation between the V·O2 the fresh gas, and FIO2 in a semi-closed circle breathing system. By adopting a "volume-weighted average concentration" approach and stepwise calculations, we have proposed an equation. We constructed a model with known simulated O2 consumption (SIM V· O2) to test our equation and two other previous methods (Biro's and Azami's). After 32 different laboratory scenarios, the %-error of the calculated V·O2 (CAL V·O2) from our method is -4.0 ± 2.9%, which is significantly better than those from Azami's method (-8.8 ± 6.2%, p < 0.01) and from Biro's method (-27.4 ± 5.1%, p < 0.01). We also produce a Bland-Altman analysis of our CAL V·O2 and SIM V·O 2 The 95% limits of agreement are -18.6-3.3 mL/min with a mean bias of -7.7 mL/min, which shows a good agreement. Our equation also explains the difference between FIO2 and the oxygen concentration of the fresh gas in a semi-closed circle breathing system.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback