Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Optimizing the TLD-100 readout system for various radiotherapy beam doses using the Taguchi methodology
 
  • Details
Options

Optimizing the TLD-100 readout system for various radiotherapy beam doses using the Taguchi methodology

Journal
Applied Radiation and Isotopes
Date Issued
2010-03-01
Author(s)
CHIEN-YI CHEN  
DOI
10.1016/j.apradiso.2009.12.001
URI
https://www.scopus.com/pages/publications/74849138024
https://scholars.csmu.edu.tw/handle/123456789/25214
Abstract
The TLD-100 readout system was optimized for various radiotherapy beam doses using the Taguchi method. The radiotherapy beam was produced by a Varian 21EX linear accelerator (LINAC) at 6 MV. The beam doses were 50, 100 and 150 cGy, and the measured data in each group were averaged from three TLD-100 chips. A total of nine combinations of four parameters were arranged, in the manner suggested by Taguchi. The four parameters were defined as initial temperature, heating rate, preheat time and maximum set temperature of the readout system during TLD reading. The loss function η adopted herein was specifically defined to satisfy the requirements of both sharp linearity and good reproducibility of the TLD reading at various radiotherapy beam doses. The optimized values were: (1) 50 {ring operator} C for initial temperature, (2) 3 {ring operator} C / s for heating rate, (3) 5 min for the TLD preheat time and (4) 250 {ring operator} C for the maximum temperature for TLD reading. Additionally, the parameters that dominated the TLD readout were: (1) initial temperature, (2) heating rate and (4) maximum temperature setting for TLD reading; and the minor parameter was (3) TLD preheat time before reading. The interactions among the dominant parameters were also studied: no significant cross interaction occurred between initial temperature and heating rate or between initial temperature and maximum temperature. However, a complex cross-interaction existed between optimal heating rate and maximum temperature.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback