Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. The development of human animation figures using 3D anthropometrical database
 
  • Details
Options

The development of human animation figures using 3D anthropometrical database

Journal
SAE Technical Papers
Date Issued
2008-01-01
Author(s)
YEN-HUI LIN  
DOI
10.4271/2008-01-1924
URI
https://www.scopus.com/pages/publications/85072479428
https://scholars.csmu.edu.tw/handle/123456789/25564
Abstract
The objective of this study is to develop 3D animation human figures using an existing anthropometrical database-the Taiwanese 3D BodyBank with 135 male and female subjects. Each subject was scanned with 9 postures, one of standing postures was designated as "standard" to develop animation figures, and the other 8 were used for evaluation purpose. The database was stratified into 15 different body size groups, 5 heights and 3 weights, for the development of 15 animation figures each for the males and the females. For both genders, we began with the establishment of a prototype model of the animation figure on the median body size group. The developing of the prototype model is proceeded as (1) the selection of representative model within each body size group, (2) the design of the skeleton, (3) the definition of spherical coordinate system, (4) the organization of data structure, (5) the implantation of the skeleton, and (6) the binding of the surface data with the skeleton. The results of the prototype model were evaluated on accuracy and precision by superimposing the animated postures onto the 8 scanned postures. The finding showed that the average mismatching errors were all smaller than 10 mm. and the maximal mismatching errors were smaller than 16 mm. This prototype model was applied onto the rest of 14 body types using template matching method.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback