Options
有限元素分析自然牙併合植體贋復體之橋體跨距設計之生物力學
Date Issued
2024
Author(s)
黃齡萱
HUANG, LING-SHIUAN
Advisor
丁信智
Abstract
現今,無論年輕人或老年人,因齲齒、牙周病或牙齒斷折等原因導致牙齒缺失而以自然牙或植體為支柱之牙橋贋復體重建咬合功能已成為臨床牙科常見的治療計畫。牙橋贋復體在咬合負載下的穩定性不僅受到連接器和植體基台設計的影響,同時牙橋跨距也為影響因素之一。然而,較少文獻著墨於牙橋跨距的探討。因此,本研究的目的是在探討不同跨度距離的自然牙併合植體支撐修復體 (Tooth-implant supported prosthesis, TISP) 於不同植體基台設計與剛性及非剛性連接器於整體牙橋系統之生物力學應力分佈,進而提供臨床醫師於自然牙併合植體支撐修復體之優化設計。為了進行比較分析,剛性和非剛性牙橋連接配備了三種植體基台系統(一件式、兩件式和三件式)和五種植體到自然牙的距離配置( 12 mm、14 mm、16 mm、18 mm和 20 mm)。研究發現TISP組件間最大應力出現在一件式剛性連接體組的黏合劑1冠緣遠端和一件式非剛性連接體組的牙冠3底部,其餘各組較為集中植體頸部邊緣內側與基台之間的交界處。此外,剛性連接器模型和非剛性連接器模型均未顯示應力分佈隨橋跨距離成比例增加。綜合上述,臨床上推薦若植體距離天然牙橋距較短(12 mm),可採用三件式基台之剛性連接作為TISP設計。如果橋距較長(18 mm),三件式基台的非剛性連接可以維持天然牙的生理運動,避免植體周圍骨嵴承受過大的應力。
From nowadays, people missing teeth or loss of occlusion dimension due to dental caries, periodontal disease, or tooth fracture, etc… was common situations, no matter in young or elder aged. To reconstructed patient occlusion, one of the most important conditions was bridge stability under loading and influenced by bridge span with the connector and implant abutment design. Thus, the purpose of this study was to evaluate the effects of rigid and non-rigid connector designs and pontic connections of different abutment systems in the tooth-implant supported prosthesis (TISP) at different span distances on the biomechanical stress distribution of the overall system components. For comparative analysis, rigid and non-rigid bridge connections were fitted with three implant abutment systems (one-piece, two-piece and three-piece), and five implant-to-natural tooth distance configurations (12 mm, 14 mm, 16 mm, 18 mm, and 20 mm) were provided. As a result, the maximum stress between TISP components occurred at the distal side of crown margin of cement1 in rigid connector with one-piece group and the bottom of the crown3 in non-rigid connector with one-piece group, while the other groups were more concentrated at the junction between the mesial side of the implant collar and the abutment. In addition, neither the rigid nor non-rigid connector model showed that stress distribution increased proportionally with the bridge span distance. In conclusion, it was clinically recommended that if the implant with a shorter bridge distance of 12 mm from the natural tooth, the rigid connection of the three-piece abutment can be used as the TISP design. If the bridge distance was 18 mm longer, the non-rigid connection of the three-piece abutment could maintain the physiological movement of the natural tooth and avoid the excessive stress on the bone crest around the implant.
Subjects
自然牙併合植體贋復體
生物力學
非剛性連接器
橋跨距離
有限元素分析
Tooth-implant supported prosthesis
Biomechanics
Non-rigid connector
bridge span distance
Finite element analysis
Type
thesis
File(s)
No Thumbnail Available
Name
112CSMU0592002-001.pdf
Size
5.46 MB
Format
Adobe PDF
Checksum
(MD5):620ac4b51315eb41b652f8b1df9d8b51