Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Effects of different aligner materials and attachments on orthodontic behavior
 
  • Details
Options

Effects of different aligner materials and attachments on orthodontic behavior

Journal
Journal of Dental Sciences
Date Issued
2021-07-01
Author(s)
CHUN-TE HO
TSUI-HSIEN HUANG
CHIA-TZE KAO  
DOI
10.1016/j.jds.2021.01.011
URI
https://www.scopus.com/pages/publications/85100688920
https://scholars.csmu.edu.tw/handle/123456789/27843
Abstract
Background/purpose: The orthodontic aligner becomes popular worldwide in orthodontic therapy as an esthetic alternative to fixed labial braces. This study evaluated orthodontic tooth movement behavior using different aligner materials and attachment shapes for the movement of a single tooth. Materials and methods: First bicuspid extracted resin typodont models were printed with a 3D printer. Three type of attachments, an ellipsoid shape (thick and thin) and a bar, were designed to fit the canine crown surface. Three types of aligner materials, Polyethylene Terephthalate enhanced with glycol (BIOSTAR) Polyethylene Terephthalate (BenQ), and Thermoplastic polyurethanes (TPU) were used to fabricate different aligners. The typodonts with aligners were sunk in a water bath to simulate canine distal movement in vivo. The canine crown, root movement, and long axis angle changes in each step were calculated and recorded. The data were analysed using a oneway ANOVA statistical method. Results: Comparing the three aligners, the changes the long axis of the canine showed that the BENQ group had a smaller change in the long axis angle. The BENQ group canine involved bodily movement, but the canine movement of the BIOSTAR and TPU group involved tipping. Comparing the three attachments, the bar type attachment had more canine crown tipping in the BIOSTAR and TPU groups. The thick and thin ellipsoid-shaped attachments showed no statistical differences in tooth movement. Conclusion: Attachment shape or size had little influence on the bodily movement of the tooth. A high modulus material may thus be suitable for clinical applications.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback