Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Numerical analysis of an immunochromatographic test strip reader in abused drugs screening
 
  • Details
Options

Numerical analysis of an immunochromatographic test strip reader in abused drugs screening

Journal
Journal of Immunoassay and Immunochemistry
Date Issued
2012-04-01
Author(s)
YAN-ZIN CHANG  
DOI
10.1080/15321819.2011.618862
URI
https://www.scopus.com/pages/publications/84859732102
https://scholars.csmu.edu.tw/handle/123456789/22338
Abstract
A point-of-care immunoassay strip reader, Uniscan™, was applied to detect methamphetamine, opiate, and marijuana in human urine by providing numerical apparent drug concentrations. Calibration curves were determined by a nonlinear regression. The cutoff was verified using spiked controls. Clinical samples were analyzed and compared with enzyme multiplied immunoassay technique (EMIT). The discrepant results were confirmed by gas chromatography-mass spectrometry (GC-MS). The impacts of interference and cross-reactivity were determined for numerous compounds. The coefficients of the calibration curves had a high correlation coefficient. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and total recovery all had high values for spiked controls. For the 19 discrepant results of clinical samples, GC-MS confirmed that Uniscan and EMITwere correct for 11 and eight samples, respectively. For both methamphetamine and opiate, Uniscan had a lower false positive rate, a higher true negative rate, and a higher total recovery rate than EMIT. For marijuana, Uniscan had a higher true positive rate and a lower false negative rate than EMIT. The Uniscan performed excellently when compared to EMIT. It is advantageous for Uniscan to interpret the test result based on digital read-out, rather than subjective visual judgment.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback