The effective dose assessment of C-arm CT in hepatic arterial embolisation therapy

Journal
British Journal of Radiology
Date Issued
2013-04-01
Author(s)
Yeu-Sheng Tyan  
TOU-RONG CHEN  
DOI
10.1259/bjr.20120551
URI
https://www.scopus.com/pages/publications/84876052312
https://scholars.csmu.edu.tw/handle/123456789/23373
Abstract
Objective: To assess the effective dose of the liver C-arm computed tomography (CT) scan during hepatic arterial embolisation surgery with clinical dose-area product (DAP) data from Taiwan. Methods: The experiment used two kinds of phantoms: RANDO® Man and RANDO Woman (The Phantom Laboratory, Salem, NY), embedded with thermoluminescent dosemeters at locations according to the International Commission on Radiological Protection 103 report. The conversion factors of DAP to effective doses for males and females, respectively, were obtained. The clinical DAP data of liver C-arm CT scan during hepatic arterial embolisation surgery were collected in a hospital in Taiwan. Results: There were 125 liver transarterial embolisation therapy cases, including 94 males and 31 females, from February 2009 to June 2010. C-arm CT was used 38 times for males and 17 times for females. The corresponding average and standard deviation of clinical DAP were 61.0±6.6 Gycm2 and 52.2±8.3 Gy cm2, respectively. Conclusion: The DAP of RANDO Man and RANDO Woman phantoms simply scanned by C-arm CT are much lower than that of patients. After consideration of the clinical DAP of patients, the effective doses of a liver C-arm CT scan recommended for males and females in Taiwan are 11.5±2.3mSv and 11.3±3.0 mSv, respectively. Advances in knowledge: The conversion factors of DAP to effective doses for males and females are 0.19±0. 03mSvGy-1cm-2 and 0.22±0.05mSvGy -1cm-2. Only if the actual DAP value of a patient scan is multiplied by the conversion factor can the correct effective dose be determined.