Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Calculating air volume fractions from computed tomography images for chronic obstructive pulmonary disease diagnosis
 
  • Details
Options

Calculating air volume fractions from computed tomography images for chronic obstructive pulmonary disease diagnosis

Journal
PLOS ONE
Date Issued
2020-04-01
Author(s)
CHUN-CHAO CHUANG  
SHAN-CHIH LEE  
Yeu-Sheng Tyan  
DOI
10.1371/journal.pone.0231730
URI
https://www.scopus.com/pages/publications/85083364875
https://scholars.csmu.edu.tw/handle/123456789/27301
Abstract
Quantitative evaluation using image biomarkers calculated from threshold-segmented lowattenuation areas on chest computed tomography (CT) images for diagnosing chronic obstructive pulmonary diseases (COPD) has been widely investigated. However, the segmentation results depend on the applied threshold and slice thickness of the CT images because of the partial volume effect (PVE). In this study, the air volume fraction (AV/TV) of lungs was calculated from CT images using a two-compartment model (TCM) for COPD diagnosis. A relative air volume histogram (RAVH) was constructed using the AV/TV values to describe the air content characteristics of lungs. In phantom studies, the TCM accurately calculated total cavity volumes and foam masses with percent errors of less than 8% and ±4%, respectively. In patient studies, the relative volumes of normal and damaged lung tissues and the damaged-to-normal RV ratio were defined and calculated from the RAVHs as image biomarkers, which correctly differentiated COPD patients from controls in 2.5- A nd 5-mm-thick images with areas under receiver operating characteristic curves of >0.94. The AV/TV calculated using the TCM can prevent the effect of slice thickness, and the image biomarkers calculated from the RAVH are reliable for diagnosing COPD.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback