Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. College of Medicine /醫學院
  3. Institute of Medicine/醫學研究所
  4. 應用ICON非侵入性血流動力學監測系統評估第二型糖尿病患者心血管狀態之變化
 
  • Details
Options

應用ICON非侵入性血流動力學監測系統評估第二型糖尿病患者心血管狀態之變化

Date Issued
2020
Author(s)
劉翔婷
Shiang-Ting Liu
Advisor
林志立
黃建寧  
Chih-Li Lin  
Chien-Ning Huang  
URI
https://handle.ncl.edu.tw/11296/74xax8
https://scholars.csmu.edu.tw/handle/123456789/36535
Abstract
糖尿病為二十一世紀罹患率增加最快的慢性疾病,其是導致失明、腎臟衰竭、心臟病、中風及下肢截肢的主要原因。糖尿病被認為與微血管及大血管的併發症有密切相關,微血管(microvascular)併發症是指視網膜病變、腎病變及神經病變等,在糖尿病患者中非常普遍,然而持續的血糖控制不穩,進而容易引發大血管(macrovascular)併發症的發生,而大血管病變包含心血管疾病及周邊動脈疾病。糖尿病所引起的大血管及微血管病變,在臨床上能被確診時大多為病況較嚴重,或者已有症狀發生時,但現行能早期監測到患者血液動力學之肺動脈導管Pulmonary artery catheter(PAC)及Pulse-induced contour cardiac output(PiCCO)皆屬侵入性治療,在糖尿病患者回門診追蹤病況時並不適用。故在本研究中使用非侵入性血流動力學監測儀(ICONTM)取代侵入性檢查,獲取患者血液動力學之測量數值。本研究以前瞻性世代研究(prospective cohort study),自2018年11月份至2019年11月份之間於糖尿病新陳代謝科門診隨機收案245名疾病組,以及於成人健檢中心隨機收案43名健康對照組。運用MATLAB程式碼統計,運算出疾病組與控制組各個參數的相關性,P-value <0.01之參數有HbA1C、心跳(HR)、每次心搏量(SV)、心收縮力指數(ICON)、心搏量指數(Stroke Volume Index;SI)、收縮壓(SYS)、平均動脈壓(MAP)、體循環阻力(SVR)、體循環阻力指數(SVRI [BSA])、預射血期(PEP)、左心室射血期(LVET),進而將這些參數運用程式碼,分析出相關係數分佈圖、P-value、三維圖、分成4個族群、機器學習、機器辨識等結果,運用Classification APP進行機器學習辨識疾病組與控制組顯著分群之分佈圖,期望藉此於未來能有效應用在臨床診斷,幫助監控及預防糖尿病患者發生血管病變相關的合併症。
Diabetes is the fastest-growing chronic disease in the 21st century. It is the main cause of blindness, kidney failure, heart disease, stroke and amputation of lower extremities. Diabetes is closely related to the complications of microvascular and macrovascular. Complications refer to retinopathy, nephropathy, neuropathy, etc., which are very common in diabetic patients. However, macrovascular complications can be found on continuous unstable blood sugar control, which can easily lead to cardiovascular diseases and peripheral arterial disease. Diabetes-caused macrovascular and microvascular lesions, most of which are more serious when they can be diagnosed clinically, or when symptoms have occurred, but the current pulmonary artery catheters and PiCCO that can early detect patient hemodynamics are invasive treatments, not applicable when diabetic patients return to the clinic to track their condition. Therefore, in this study, a non-invasive hemodynamic monitor (ICONTW) was used to replace the invasive examination to obtain the measured value of the patient's hemodynamics. A prospective cohort study was conducted. From November 2018 to November 2019 at a medical center in central Taiwan, 245 disease groups were randomly admitted in the outpatient department of the Department of Diabetes Metabolism, and 43 healthy controls were also randomly accepted in the adult health examination center. We used MATLAB program statistics to calculate the correlation between various parameters of the disease group and the control group. The parameters with P-value <0.01 are HbA1C, heart rate (HR), stroke volume (SV), Index of Contractility (ICON), stroke volume Index (Stroke Index; SI), systolic blood pressure (SBP), mean blood pressure (MAP), Systemic Vascular Resistance (SVR), peripheral vascular resistance index (SVRI [BSA]), pre-ejection period (PEP), left ventricular ejection(LVET), and then use these codes to analyze the correlation coefficient distribution map, P-value, three-dimensional map, machine learning, machine identification and other results by dividing into 4 groups. Moreover, we also performed Classification APP of machine learning to identify disease groups, and the distribution map of the significant grouping of the control group. In conclusion, we expect our results may be effectively used in clinical diagnosis in the future to help monitor and prevent comorbidities associated with vascular disease in diabetic patients.
Subjects
第二型糖尿病
血流動力學
非侵入性血流動力學監測
Type 2 diabetes mellitus
hemodynamic
Non-Invasive Hemodynamics monitoring
Type
thesis
File(s)
No Thumbnail Available
Name

108CSMU5534043-001.zip

Size

5.92 MB

Format

Unknown

Checksum

(MD5):bf308e93d58883a808a94d389c286a21

Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback