Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. A magneto-microfluidic platform for fluorescence immunosensing using quantum dot nanoparticles
 
  • Details
Options

A magneto-microfluidic platform for fluorescence immunosensing using quantum dot nanoparticles

Journal
Nanotechnology
Date Issued
2019-09-26
Author(s)
HWEI-YAN TSAI
DOI
10.1088/1361-6528/ab423d
URI
https://www.scopus.com/pages/publications/85074304213
https://scholars.csmu.edu.tw/handle/123456789/34304
Abstract
This study reports the online fluorescent detection of carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) biomarker proteins in microfluidic channels using functional nanoparticles. Functional magnetic nanoparticles labeled with two antibodies were predeposited on separated microfluidic channels. Antigens were passed through each microfluidic channel to react with the respective antibodies. Two types of fluorescent nanoparticles labeled with antibodies were then used to detect and confirm antigens in the immunocomplex. Results indicate that online fluorescent detection of proteins can provide advantages for real-time monitoring and diagnostic applications. The running time was less than 20 min for each trial. The detection limits of CEA and AFP were found to be 0.6 and 0.2 pg ml-1. These detection limits are lower than those of ELISA. The linear ranges of CEA and AFP detection were from 1.8 pg ml-1 to 1.8 ng ml-1 and from 0.68 pg ml-1 to 0.68 ng ml-1 for two deposition zones in a magnetic sandwich immunoassay. The linear ranges of this method are wider than those of ELISA and those of most other methods. The measurements of CEA and AFP in serum samples from this method differed from ELISA results by 11% and 9.4%, respectively. The detection limit of online detection has achieved the same range as those of previous offline detection. This method has a good potential for automation and multichannel analysis to increase the throughput with some modifications in the future. The proposed method can provide simple, fast, and sensitive online detection for biomarkers.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback