Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Temporal/seasonal variations of size-dependent airborne fungi indoor/outdoor relationships for a wind-induced naturally ventilated airspace
 
  • Details
Options

Temporal/seasonal variations of size-dependent airborne fungi indoor/outdoor relationships for a wind-induced naturally ventilated airspace

Journal
Atmospheric Environment
Date Issued
2004-08-01
Author(s)
SZU-CHIEH CHEN  
DOI
10.1016/j.atmosenv.2004.04.029
URI
https://www.scopus.com/pages/publications/3142600692
https://scholars.csmu.edu.tw/handle/123456789/31190
Abstract
With the use of published temporal/seasonal size characteristics of fungal spores and meteorological data in the subtropical climate, we estimated the airborne fungal concentration indoor/outdoor (I/O) ratios in a wind-induced naturally ventilated home. We expanded previous size-dependent indoor air quality model based on a hygroscopic growth factor as a function of relative humidity (RH) on aerodynamic diameter and concentration of fungal spores. The average geometric mean diameters of airborne fungi decreased from outdoor 2.58±0.37 to indoor 1.91±0.12μm in summer, whereas decreased from outdoor 2.79±0.32 to indoor 1.73±0.10μm in winter, resulting from the effect of hygroscopicity of airborne fungi. The higher indoor airborne fungal concentrations occurred in early and late afternoon in which median values were 699.29 and 626.20CFUm-3 in summer as well as 138.71 and 99.01CFUm-3 in winter, respectively, at 2 a.m. and 8 p.m. In the absence of indoor sources, summer has higher mean I/O ratios of airborne fungal concentration (0.29 - 0.58) than that in winter (0.12 - 0.16). Parsimoniously, our proposed RH-corrected I/O ratio model could be used to estimate the indoor source concentrations of bioaerosols provided that the actual measured fungus-specific I/O ratios are available.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback