Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Simultaneous determination of voriconazole and its metabolites in human plasma by capillary electrophoresis with cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography
 
  • Details
Options

Simultaneous determination of voriconazole and its metabolites in human plasma by capillary electrophoresis with cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography

Journal
Analytical Methods
Date Issued
2025-05-27
Author(s)
PEI-MING CHU  
DOI
10.1039/d5ay00552c
URI
https://www.scopus.com/pages/publications/105005942232
https://scholars.csmu.edu.tw/handle/123456789/26809
Abstract
This study presents a highly efficient analytical approach combining cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography with photodiode array detection for the simultaneous determination of voriconazole (VRC) and its key metabolites, voriconazole N-oxide (VNO) and hydroxy-voriconazole (V-OH), in human plasma. The method utilizes a precisely optimized capillary electrophoresis system with the following conditions: an uncoated fused-silica capillary (30 cm, 50 μm I.D.) filled with phosphate buffer (125 mM, pH 2.5) containing 15% (v/v) acetonitrile and 10% (v/v) propanol, followed by a high-conductivity buffer zone (100 mM phosphate, pH 2.5, 8.3 kPa, 99.9 s). After electrokinetic injection (10 kV, 600 s) of cationic analytes, separation was achieved under −20 kV using phosphate buffer (50 mM, pH 2.5) containing 200 mM sodium dodecyl sulfate. Detection was set at 214 nm. This optimized method demonstrated excellent sensitivity, with a detection limit (S/N = 3) of 0.01 μg mL−1 for all analytes. The sensitivity was increased by 200 times compared to the conventional MEKC method. The calibration curves showed good linearity, with correlation coefficients exceeding 0.9995 over the ranges of 0.1-10.0 μg mL−1 for VRC, 0.05-5.0 μg mL−1 for VNO, and 0.05-1.0 μg mL−1 for V-OH. Precision and accuracy assessments revealed relative standard deviations (RSDs) and relative errors (REs) of less than 7.2% and 5.2%, respectively. This method has been successfully applied to real plasma samples from patients. It can provide more accurate drug exposure information to assist VRC dosage adjustments, thus improving VRC treatment, and can also be applied in VRC pharmacokinetic studies.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback