Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Improvement of the Image Quality of Black-blood Magnetic Resonance Imaging with the Subtraction Double Inversion Recovery Technique
 
  • Details
Options

Improvement of the Image Quality of Black-blood Magnetic Resonance Imaging with the Subtraction Double Inversion Recovery Technique

Journal
Journal of Radiological Science
Date Issued
2014-12-01
Author(s)
CHAO-YU SHEN  
Yeu-Sheng Tyan  
DOI
10.6698/JRS.201412_3904.01
URI
https://www.scopus.com/pages/publications/85160213343
https://scholars.csmu.edu.tw/handle/123456789/29149
Abstract
Black-blood images acquired with the double inversion recovery (IR) sequence in cardiovascular magnetic resonance imaging are commonly applied to distinguish the vessel wall from the lumen to evaluate vascular pathology. However, inadequate suppression of blood signals may introduce artifacts and cause mistakes. The objective of the current study was to determine whether subtraction double IR black-blood imaging improved the image quality. 11 scans from four rabbits were scanned using the conventional and subtraction T1 weighted double IR imaging. The subtraction method involved two scans with a third IR sequence with a series of inversion time (TI) settings in one of them. Each black-blood image was qualitatively evaluated based on contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR), and noises. Using the best TI setting (575 ms), subtraction black-blood imaging yielded significantly better black-blood effects with a 48.6% increase in mean CNR between the area of the left carotid artery and adjacent paravertebral muscles (PM) and a 30.7% increase in mean CNR between the area of the left jugular vein and adjacent PM compared with the conventional method (5.65 vs. 3.81 and 6.8 vs. 5.21, both p values < 0.05). The subtraction black-blood imaging did not significantly deteriorate image quality regarding noises and mean SNRs in the area of PM. Subtraction double IR black-blood imaging is better than the conventional method in black-blood effects of blood signals.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback