Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Detection of c-reactive protein based on a magnetic immunoassay by using functional magnetic and fluorescent nanoparticles in microplates
 
  • Details
Options

Detection of c-reactive protein based on a magnetic immunoassay by using functional magnetic and fluorescent nanoparticles in microplates

Journal
Analyst
Date Issued
2014-01-01
Author(s)
HWEI-YAN TSAI
DOI
10.1039/c4an00921e
URI
https://www.scopus.com/pages/publications/84908319415
https://scholars.csmu.edu.tw/handle/123456789/24870
Abstract
We report the preparation and application of biofunctional nanoparticles to detect C-reactive protein (CRP) in magnetic microplates. A CRP model biomarker was used to test the proposed detection method. Biofunctional magnetic nanoparticles, CRP, and biofunctional fluorescent nanoparticles were used in a sandwich nanoparticle immunoassay. The CRP concentrations in the samples were deduced from the reference plot, using the fluorescence intensity of the sandwich nanoparticle immunoassay. When biofunctional nanoparticles were used to detect CRP, the detection limit was 1.0 ng ml-1 and the linear range was between 1.18 ng ml-1and 11.8 μg ml-1. The results revealed that the method involving biofunctional nanoparticles exhibited a lower detection limit and a wider linear range than those of the enzyme-linked immunosorbent assay (ELISA) and most other methods. For CRP measurements of serum samples, the differences between this method and ELISA in CRP measurements of serum samples were less than 13%. The proposed method can reduce the analysis time to one-third that of ELISA. This method demonstrates the potential to replace ELISA for rapidly detecting biomarkers with a low detection limit and a wide dynamic range.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback