Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Application of an artificial neural network to predict postinduction hypotension during general anesthesia
 
  • Details
Options

Application of an artificial neural network to predict postinduction hypotension during general anesthesia

Journal
Medical Decision Making
Date Issued
2011-03-01
Author(s)
JUI-AN LIN  
DOI
10.1177/0272989X10379648
URI
https://www.scopus.com/pages/publications/79953836782
https://scholars.csmu.edu.tw/handle/123456789/31453
Abstract
Background. Perioperative hypotension is associated with adverse outcomes in patients undergoing surgery. A computer-based model that integrates related factors and predicts the risk of hypotension would be helpful in clinical anesthesia. The purpose of this study was to develop artificial neural network (ANN) models to identify patients at high risk for postinduction hypotension during general anesthesia. Methods. Anesthesia records for March through November 2007 were reviewed, and 1017 records were analyzed. Eleven patient-related, 2 surgical, and 5 anesthetic variables were used to develop the ANN and logistic regression (LR) models. The quality of the models was evaluated by an external validation data set. Three clinicians were asked to make predictions of the same validation data set on a case-by-case basis. Results. The ANN model had an accuracy of 82.3%, sensitivity of 76.4%, and specificity of 85.6%. The accuracy of the LR model was 76.5%, the sensitivity was 74.5%, and specificity was 77.7%. The area under the receiver operating characteristic curve for the ANN and LR models was 0.893 and 0.840. The clinicians had the lowest predictive accuracy and sensitivity compared with the ANN and LR models. Conclusions. The ANN model developed in this study had good discrimination and calibration and would provide decision support to clinicians and increase vigilance for patients at high risk of postinduction hypotension during general anesthesia.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback