Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Effects of interfacial debonding on fatigue damage of cemented hip prostheses
 
  • Details
Options

Effects of interfacial debonding on fatigue damage of cemented hip prostheses

Journal
Journal of the Chinese Institute of Engineers, Transactions of the Chinese Institute of Engineers,Series A/Chung-kuo Kung Ch'eng Hsuch K'an
Date Issued
2003-01-01
Author(s)
JIAN-HORNG CHEN  
DOI
10.1080/02533839.2003.9670833
URI
https://www.scopus.com/pages/publications/0345412034
https://scholars.csmu.edu.tw/handle/123456789/29498
Abstract
Clinical studies on retrieved cement mantles have pointed out that the cemented hip prostheses failed after long-term use due to debonding at the cement-stem interface and local fractures in the cement mantles. These were linked to fatigue damages of cement mantles proved by fatigue experiments. In this paper, a numerical approach based on finite element analysis and continuum damage mechanics is proposed to investigate the fatigue behavior of cement mantles during gait cycles. Results reveal that the major sites for failure initiation are at the proximal medial regions and at the distal prostheses tip. Such fatigue failures not only result in the corruption of cementstem interfaces, but also greatly affect the stress distribution and damage rate of the proximal cement mantles in subsequent loading cycles. The interfacial debonding rate increases from 2.5% to 15% with gait loadings from five to twenty million cycles. Meanwhile, owing to the partial debonding of interface, the cement stresses on the remaining regions increase by 91% to 871% when compared with those generated with a fully bonded interface, which in turn accelerates the fatigue damage accumulation rate of the cement mantle from 5.99 % to 21.5%.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback