  4. Solution-Induced Degradation of the Silicon Nanobelt Field-Effect Transistor Biosensors
 
  • Details
Options

Solution-Induced Degradation of the Silicon Nanobelt Field-Effect Transistor Biosensors

Journal
Biosensors
Journal Volume
14
Journal Issue
2
Start Page
65
ISSN
2079-6374
Date Issued
2024-01-25
Author(s)
Jung-Chih Lin  
Zhao-Yu Zhou
Yi-Ching Cheng
I-Nan Chang
Chu-En Lin
Chi-Chang Wu
DOI
10.3390/bios14020065
URI
https://scholars.csmu.edu.tw/handle/123456789/4935
Abstract
<jats:p>Field-effect transistor (FET)-based biosensors are powerful analytical tools for detecting trace-specific biomolecules in diverse sample matrices, especially in the realms of pandemics and infectious diseases. The primary concern in applying these biosensors is their stability, a factor directly impacting the accuracy and reliability of sensing over extended durations. The risk of biosensor degradation is substantial, potentially jeopardizing the sensitivity and selectivity and leading to inaccurate readings, including the possibility of false positives or negatives. This paper delves into the documented degradation of silicon nanobelt FET (NBFET) biosensors induced by buffer solutions. The results highlight a positive correlation between immersion time and the threshold voltage of NBFET devices. Secondary ion mass spectrometry analysis demonstrates a gradual increase in sodium and potassium ion concentrations within the silicon as immersion days progress. This outcome is ascribed to the nanobelt’s exposure to the buffer solution during the biosensing period, enabling ion penetration from the buffer into the silicon. This study emphasizes the critical need to address buffer-solution-induced degradation to ensure the long-term stability and performance of FET-based biosensors in practical applications.</jats:p>
SDGs

[SDGs]SDG3

Publisher
MDPI AG
Type
journal-article