Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Prevention of the initiation of atrial fibrillation
 
  • Details
Options

Prevention of the initiation of atrial fibrillation

Other Title
Mechanism and efficacy of different atrial pacing modes
Journal
PACE - Pacing and Clinical Electrophysiology
Date Issued
2000-01-01
Author(s)
CHIN-FENG TSAI  
DOI
10.1111/j.1540-8159.2000.tb06764.x
URI
https://www.scopus.com/pages/publications/0038451031
https://scholars.csmu.edu.tw/handle/123456789/25551
Abstract
Several atrial pacing modes have been reported to be effective in the prevention of atrial fibrillation (AF); they included biatrial pacing, dual site right atrial pacing, Bachmann's bundle (BB) pacing, and coronary sinus pacing. However, the relative efficacy and electrophysiological mechanisms of these pacing modes in the prevention of AF are not clear. In 15 patients (age 54 ± 14 years) with paroxysmal AF, P wave duration, effective refractory period, and atrial conduction time were determined with six different atrial drive pacings, that were right atrial appendage (RAA), BB, right posterior interatrial septum (RPS), distal coronary sinus (DCS), RAA plus RPS simultaneously (DSA), and BAA plus DCS simultaneously (BiA). All these patients consistently had AF induced with early RAA extrastimulation coupling to RAA drive pacing. No patient had AF induced with BAA extrastimulation coupled to BB, RPS, or DCS drive pacing, but seven and eight patients had AF induced with RAA extrastimulation coupled to DSA and BiA drive pacing, respectively. The P wave duration was longest during RAA pacing, and became shorter during other atrial pacing modes. Analysis of electrophysiological change showed that early RAA extrastimulation coupled to RAA drive pacing caused the longest atrial conduction delay among these atrial pacing modes; BB, RPS, and DCS drive pacing caused a greater reduction of this conduction delay than DSA and BiA drive pacing. In addition, the effective refractory periods of RAA determined with BB, RPS, and DCS drive pacing were similar and longer than that determined with DSA and BiA drive pacing. In patients with paroxysmal AF, this arrhythmia was readily induced with BAA extrastimuli coupled to RAA drive pacing. BB, RPS, and DCS pacing were similar and more effective than DSA and BiA pacing in preventing AF.
Type
journal article