Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Chung Shan Medical University
  3. Pure學術人才庫轉入
  4. Development of wearable posture monitoring system for dynamic assessment of sitting posture
 
  • Details
Options

Development of wearable posture monitoring system for dynamic assessment of sitting posture

Journal
Physical and Engineering Sciences in Medicine
Date Issued
2020-03-01
Author(s)
CHUN-YU YEH  
DOI
10.1007/s13246-019-00836-4
URI
https://www.scopus.com/pages/publications/85088303278
https://scholars.csmu.edu.tw/handle/123456789/24216
Abstract
There have been increasing cases of people seeking treatment for neck and back pain. The most common cause of neck and back pain is due to long-term poor sitting posture. The most common poor sitting posture cases are humpback, and head and neck being too far forward. It is easy to cause neck and back pain and other symptoms. Therefore, the development of wearable posture monitoring system for dynamic assessment of sitting posture becomes both helpful and necessary. In addition to recording the wearer’s posture when sitting with quantitative assessment, it is needed to execute real-time action feedback for correctness of posture, in order to reduce neck and back pain due to long-term poor sitting posture. This study completed an instant recording and dynamic assessment of position measurement and feedback system. The system consists of a number of dynamic measurement units that can describe the posture trajectory, which integrates three-axis gyro meter, three-axis accelerometer, and magnetometer in order to measure the dynamic tracking. In the reliability analysis experiment, angle measurement error is less than 2%. The correlation coefficient between correlation analysis and Motion Analysis (MA) is 0.97. It is shown that the motion trajectory of this system is highly correlated with MA. In the feasibility test of sitting position detection, it is possible to detect the sitting position from the basic action of the walking, standing, sitting and lying down, and the sensitivity reaches 95.84%. In the assessment of the sitting position, the information published by the Canadian Centre for Occupational Health and Safety was used, as well as the recommendations of professional physicians as a basis for evaluating the threshold of the sitting measurement parameters and immediately feedback to the subjects. The system developed in this study can be helpful to reduce neck and back pain due to long-term poor sitting posture.
Type
journal article
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback