Abstract
目的:探討亞洲年輕族群配戴矽水膠隱形眼鏡後,戴鏡後殘餘度數及戴鏡後視力值與其主觀舒適度的相關性,並同時評估受試者眼表客觀情形。方法:共計招募59 名亞洲年輕慣用矽水膠隱形眼鏡配戴者,年齡介於20~24 歲。每位受試者在研究第一週配戴somofilcon A 矽水膠鏡片,再於第二週轉換配戴verofilcon A 矽水膠鏡片。受試者均接受主觀滿意度問卷、眼表狀態評估、視覺基本檢測及視覺功能測驗。主觀滿意度問卷使用視覺類比分數問卷針對舒適度、視覺品質、乾燥程度、及滿意度線上填寫;眼表狀態評估由角膜地形圖儀評估淚液破裂時間、瞼板腺、結膜紅眼、及淚河高度;視覺基本檢測採用全視野電腦驗光儀搭配視標系統測量戴鏡後殘餘度數及視力值;視覺功能測驗包括立體視覺、近點聚合能力、遠與近距離眼位、調節靈敏度及對比敏感度測驗。結果:線性迴歸顯示配戴矽水膠隱形眼鏡somofilcon A 十五分鐘後,“戴鏡後視力值”與主觀滿意度及淚液破裂時間出現顯著負相關,分別為舒適度(B = -59.97,p = 0.015)、視覺品質(B = -59.41, p = 0.003)、滿意度(B = -47.43, p = 0.007)、初次淚液破裂時間(B = -35.18, p = 0.008)及平均淚液破裂時間(B = -19.98, p =0.044);乾燥程度為顯著正相關(B = 55.05, p = 0.042)。此時“戴鏡後殘餘度數”與淚液破裂時間產生顯著正相關,分別為初次淚液破裂時間(B = 6.64, p = 0.014)及平均淚液破裂時間(B = 5.10, p = 0.010);配戴矽水膠隱形眼鏡一週後,“戴鏡後視力值”與整體視覺品質出現顯著負相關(B = -40.46, p = 0.024)。結論:配戴矽水膠隱形眼鏡十五分鐘時,主觀滿意度問卷主要與戴鏡後視力值相關,淚液破裂時間會同時與戴鏡後殘餘度數及視力值相關;配戴一週後僅有戴鏡後視力值與主觀滿意度有顯著差異。期盼未來在臨床上能藉由更全盤性的驗配評估,提升隱形眼鏡驗配的成功率。
Purpose: To investigate the correlation of residual refraction and visual acuity tosubjective comfort rating after wearing silicone hydrogel contact lenses among youngAsian wearers, as well as assessing objective ocular performance simultaneously.Methods: A total of 59 young Asian habitual wearers of silicone hydrogel contactlenses were recruited, aged 20 to 24 years. All the recruited participants woresomofilcon A lenses at the first week and shifted to verofilcon A lenses in the secondweek. Participants underwent subjective questionnaires, ocular surface assessments,basic visual tests, and visual function examination. Subjective questionnaire wascompleted online using visual analogue scale, focusing on comfort, vision quality,dryness, and satisfaction. Ocular surface assessments were conducted using cornealtopography to evaluate tear break-up time, meibomian glands, bulbar redness, and tearmeniscus height. Basic visual tests were performed using full-field autorefractorcombined with target system to measure residual refraction and visual acuity. Visualfunction examinations included stereoacuity, near point of convergence, distance andnear phoria, accommodative facility, and contrast sensitivity.Results: The results of linear regression analysis showed that after 15 minutessomofilcon A wearing, ‘visual acuity’ had a significant negative correlation withcomfort (B = -59.97, p = 0.015), vision quality (B = -59.41, p = 0.003), satisfaction (B= -47.43, p = 0.007), first tear break-up time (B = -35.18, p = 0.008), and average tearbreak-up time (B = -19.98, p = 0.044). There was a significant positive correlation withdryness (B = 55.05, p = 0.042). “Residual refraction” had a significant positivecorrelation with first tear break-up time (B = 6.64, p = 0.014)and average tear breakuptime(B = 5.10, p = 0.010). After one week wearing, visual acuity had a significantnegative correlation with overall vision quality (B = -40.46, p = 0.024).Conclusions: When wearing silicone hydrogel contact lenses for 15 minutes, subjectivesatisfaction questionnaire is mainly related to visual acuity, while tear break-up time isrelated to both residual refraction and visual acuity. After one week wearing, only visualacuity and overall satisfaction show significant difference. It’s hoped that morecomprehensive fitting assessments in clinical practice can improve the success ofcontact lens wearing.
Subjects
戴鏡後殘餘度數
戴鏡後視力值
主觀滿意度
淚液破裂時間
residual refraction
visual acuity
subjective satisfaction
tear break-up time
Type
thesis
File(s)
No Thumbnail Available
Name
112CSMU0527006-001.pdf
Size
3.01 MB
Format
Adobe PDF
Checksum
(MD5):8cb6f718984d03252d025a86f7cf7069