林志立蔡宗博Lin,Chih-LiTsai,Tsng-Po劉庭銘Ting Ming Liu醫學研究所碩士班2026-10-292025-07-0820252025-06-18https://handle.ncl.edu.tw/11296/t2ygg2https://scholars.csmu.edu.tw/handle/123456789/36735超音波導引經皮血管成形術(PTA)為目前血液透析血管通路功能障礙處置中,一種新興且具微創性、無輻射暴露的替代方式。傳統經皮血管成形術多依賴碘劑作為X光下的顯影劑,然而碘劑不僅具腎毒性,亦可能引發過敏反應,對於慢性腎病患者而言更具潛在風險。本研究中,我們創新地採用手工注射器注入二氧化碳(CO₂)微氣泡作為超音波顯影劑,其具備不產生腎毒性、無過敏性、低成本等優勢,輔助辨識血管病灶,以改善困難或未成熟血管通路之介入治療效率。我們回顧分析2017至2018年間於台灣新竹馬偕紀念醫院執行之病例,探討此技術的臨床成效、技術成功率與安全性。本研究共納入55位接受治療之血液透析患者,依介入方式分為兩組:單純接受超音波導引PTA之第一組(n = 33),以及以手工注射CO₂微氣泡輔助超音波導引PTA之第二組(n = 22)。整體技術成功率為92.7%(51/55),其中第二組展現較短的平均手術時間(42 ± 16分鐘)、較高的技術成功率(95.4%),以及術後6個月較佳的通暢率。另有4位患者因病灶複雜需轉為傳統X光導引PTA,其中包括兩位中心靜脈狹窄、一位頭靜脈弓狹窄(第一組)與一位肱動脈病灶(第二組)。兩組皆未出現顯著之手術併發症,亦無過敏或氣體栓塞等不良反應。結論而言,超音波導引PTA為一項安全、可行且有效的血液透析血管通路治療方式,特別適用於無法使用X光或需避免碘劑的臨床情境。進一步採用手工注射CO₂微氣泡顯影劑,更可有效提升病灶辨識度與手術效率,為一種低成本、無輻射、無腎毒性、無過敏風險的替代方案。Ultrasound-guided percutaneous transluminal angioplasty (PTA) has emerged as a minimally invasive and radiation-free alternative for managing hemodialysis vascular access dysfunction. Traditionally, iodinated contrast media are used during PTA under fluoroscopic guidance; however, these agents may cause nephrotoxicity and allergic reactions, posing particular risks for patients with chronic kidney disease.In this study, we employed an innovative technique using manually injected carbon dioxide (CO₂) microbubbles as an ultrasound contrast agent to assist in visualizing vascular lesions in patients with immature or difficult arteriovenous access. We retrospectively analyzed procedures performed between 2017 and 2018 at Hsinchu Mackay Memorial Hospital, Taiwan, to evaluate clinical outcomes, technical success, and safety.A total of 55 patients were included and divided into two groups: Group 1 underwent ultrasound-guided PTA alone (n = 33), while Group 2 received ultrasound-guided PTA with CO₂ microbubbles as contrast medium (n = 22). The overall technical success rate was 92.7% (51/55). Group 2 demonstrated a shorter mean procedure time (42 ± 16 minutes), a higher technical success rate (95.4%), and superior six-month patency compared to Group 1. Four patients required conversion to conventional fluoroscopy-guided PTA due to complex lesions (two central vein stenoses, one cephalic arch stenosis in Group 1, and one brachial artery lesion in Group 2). No allergic reactions, gas embolisms, or other procedure-related complications were observed.In conclusion, ultrasound-guided PTA is a safe, effective, and feasible technique for treating hemodialysis vascular access dysfunction, particularly in resource-limited settings or in patients requiring contrast avoidance. The use of manually injected CO₂ microbubbles further enhances lesion visualization and procedural efficiency, and serves as a low-cost, radiation-free, nephrotoxicity-free, and allergy-free alternative to iodinated contrast media.二氧化碳手工注射器顯影劑過敏超音波導引血液透析經皮血管成形術Carbon dioxidehandmade syringe injectioncontrast media allergyultrasound-guided interventionhemodialysis accesspercutaneous transluminal angioplasty手工注射二氧化碳微氣泡作為顯影劑應用於超音波導引經皮血管成形術之血液透析血管通路治療之回顧性比較研究thesis